• page_head_bg

Products

UPT-4RD/LED60 Push-in type black fuse terminal blocks

Short Description:

BrieflyFor power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.

Working current: 6.3AOperating Voltage: 400 V

Wiring method: Push-in spring connection.

Rated wiring capacity: 4mm2.

Installation method: NS 35/7,5,NS 35/15


Technical Data

Product Tags

Advantage

The Push-in direct connection technology make the insertion forces reduced by up to 50 percent and tool-free wiring, enable the conductors to be inserted easily and directly.
Made from engineering flame retardants nylon PA66 with brass screw metal.

Made from engineering flame retardants nylon PA66 with brass screw metal.

●The Push-in connection terminal blocks are characterized by easy and tool-free wiring of conductors with ferrules or solid conductors.
●The compact design and front connection enable wiring in a confined space.
●In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection.

Details parameters

Product Image            
Product number UPTC-4RD UPTC-4RD/LA250 UPT-4RD/LED24 UPT-4RD/LED60 UPT-4RD/LA250 UPT-4RD/C/LED60
product type Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block
Mechanical structure Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection
layers 1 1 1 1 1 1
Electric potential 1 1 1 1 1 1
connection volume 2 2 2 2 2 2
Rated cross section 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2
Rated current 6.3A 6.3A 6.3A 6.3A 6.3A 6.3A
Rated voltage 400V 250V 24V 60V 250V 60V
open side panel Yes Yes Yes Yes Yes Yes
grounding feet no no no no no no
other The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35
Application field Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial
color (orange)、(black)、customizable (orange)、(black)、customizable (orange)、(black)、customizable (orange)、(black)、customizable (orange)、(black)、customizable (orange)、(black)、customizable
             
  • With universal foot which can be installed on Din Rail NS 35.
  • It can connect two conductors with ease, even large conductor cross sections are not a problem.
  • Electric potential distribution can use fixed bridges in the terminal center.
  • All types of accessories: End cover, End Stopper, Partition plate, marker trip, fixed bridge, insertion bridge, etc.

Details parameters:

Stripping length 8mm — 10mm 8mm — 10mm 8mm — 10mm 8mm — 10mm 8mm — 10mm 8mm — 10mm
Rigid Conductor Cross Section 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm²
Flexible conductor cross section 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm²
Rigid Conductor Cross Section AWG 24-10 24-10 24-10 24-10 24-10 24-10
Flexible Conductor Cross Section AWG 24-10 24-10 24-10 24-10 24-10 24-10
thickness 8.2mm 8.2mm 6.2mm 6.2mm 6.2mm 8.2mm
width 67.8mm 67.8mm 55.8mm 55.8mm 55.8mm 67.8mm
high 41.5mm 41.5mm 63.34mm 63.34mm 63.34mm 41.5mm
NS35/7.5 high 43mm 43mm 64.8mm 64.8mm 64.8mm 43mm
NS35/15 high            
NS15/5.5 high            
Flame retardant grade, in line with UL94 V0 V0 V0 V0 V0 V0
Insulation Materials PA PA PA PA PA PA
Insulation material group I I I I I I
  standard test IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1
Rated voltage(III/3) 500V 250V 24V 60V 250V 60V
Rated current(III/3) 6.3A 6.3A 6.3A 6.3A 6.3A 6.3A
Rated surge voltage 8kv 8kv 8kv 8kv 8kv 8kv
Overvoltage class III III III III III III
pollution level 3 3 3 3 3 3
Surge Voltage Test Results Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test
Ambient temperature (operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % — 70 %
RoHS No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances
Connections are standard IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1

  • Previous:
  • Next: