• page_head_bg

Products

UPT-6 Nylon Material Brass Button quick disconnect Push In Spring Type Screwless Connectors Contact Din Rail Terminal Blocks

Short Description:

For power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.

Working current: Operating Voltage:

Wiring method: Push-in spring connection.

Rated wiring capacity: 6mm2

Installation method: NS 35/7,5,NS 35/15


Technical Data

Business Data

Download

Certification

Product Tags

Advantage

The Push-in direct connection technology make the insertion forces reduced by up to 50 percent and tool-free wiring, enable the conductors to be inserted easily and directly.
Made from engineering flame retardants nylon PA66 with brass screw metal.
Made from engineering flame retardants nylon PA66 with brass screw metal.

●The Push-in connection terminal blocks are characterized by easy and tool-free wiring of conductors with ferrules or solid conductors.
●The compact design and front connection enable wiring in a confined space.
●In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection.
●With universal foot which can be installed on Din Rail NS 35.
●It can connect two conductors with ease, even large conductor cross sections are not a problem.
●Electric potential distribution can use fixed bridges in the terminal center.
●All types of accessories: End cover, End Stopper, Partition plate, marker trip, fixed bridge, insertion bridge, etc.

Details parameters

Product Description
Product Image      
Product Number UPT-6PE UPT-6/2-2 UPT-6
Product Type Rail wiring distribution block Rail wiring distribution block Push in din rail terminal block
Mechanical Structure Push-in spring connection Push-in spring connection Push-in spring connection
Layers 1 1 1
Electric Potential 1 1 1
Connection Volume 2 4 2
Rated Cross Section 6 mm2 6 mm2 6mm2
Rated Current 41A 41A 41A
Rated Voltage 1000V 1000V 1000V
Open Side Panel no no Yes
Grounding Feet no no no
Other The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 The connecting rail needs to install the rail foot F-NS35  
Application Field Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial
Color (green)(yellow) (gray)(dark gray)(green)(yellow)(cream)(orange)、(black(red)(blue)(white)(purple)、(Browncustomizable (gray)、(Yellow and green)、customizable
Wiring Data
Line Contact
Stripping Length 10mm — 12mm 10mm-12mm 10mm — 12mm
Rigid Conductor Cross Section 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm²
Flexible Conductor Cross Section 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm²
Rigid Conductor Cross Section AWG 20-8 20-8 20-8
Flexible Conductor Cross Section AWG 20-8 20-8 20-8
Size (This Is The Dimension Of The UPT-6PE)
Thickness 57.72mm 8.2mm 8.2mm
Width 8.15mm 90.5mm 57.7mm
High 42.2mm 42.2mm 42.2mm
NS35/7.5 High 31.1mm 51mm 51mm
NS35/15 High 38.6mm 43.5mm 43.5mm
NS15/5.5 High    
Material Properties
Flame Retardant Grade, In Line With UL94 V0 V0 V0
Insulation Materials PA PA PA
Insulation Material Group I I I
IEC  IEC Electrical Parameters
  Standard Test IEC IEC60947-1   IEC 60947-7-1
Rated VoltageIII/3   1000V 1000V
Rated CurrentIII/3   41A 41A
Rated Surge Voltage 8kv 8kv 8kv
Overvoltage Class III III III
Pollution Level 3 3 3
Electrical Performance Test
Surge Voltage Test Results Passed the test Passed the test Passed the test
Power Frequency Withstand Voltage Test Results Passed the test Passed the test Passed the test
Temperature Rise Test Results Passed the test Passed the test Passed the test
Environmental Conditions
Ambient Temperature (Operating) -40℃+105℃(Depends on the derating curve) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient Temperature (Storage/Transport)  -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient Temperature (Assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient Temperature (Execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % ... 70 % 30 % — 70 % 30 % — 70 %
Environmental Friendly
RoHS No hazardous substances above threshold values No excessive harmful substances
Standards And Specifications
Connections Are Standard IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1

  • Previous: